Efektivitas Instalasi Pengolahan Air Limbah Berdasarkan Parameter COD, BOD, TSS, pH (Studi Kasus Industri Tahu di Dusun Janten Ngestiharjo Kasihan Bantul)
DOI:
https://doi.org/10.30595/pspfs.v6i.848Keywords:
COD, BOD, TSS, pH, WWTP, EffectivenessAbstract
The liquid waste generated from tofu production process contains high Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Total Suspended Solid (TSS) as well as low pH levels or acidity. Therefore, the tofu waste needs to be treated before being discharged into the environment to prevent negative impacts on the surrounding environment. Thus, this study aimed to test the effectiveness of the tofu wastewater treatment plant by monitoring the parameters of COD, BOD, TSS and pH using the closed reflux titrimetry, gravimetri and pH meter methods. The sampling was carried out with triple sampling (triplo) at each testing point, which were the equalization tank, anaerobic baffle reactor tank, anaerobic filter tank, and final settling tank. The sample testing was conducted at the "Balai Laboratorium Kesehatan dan Kalibrasi Yogyakarta". The results of the testing were used to determine the reduction in COD and the increase in pH between the wastewater treatment plant tanks, and then the effluent of the wastewater treatment plant was compared with the wastewater quality standards. The results of this study indicate that the average reduction of COD in the effluent is 94%, BOD is 93%, and TSS is 87%. Based on these findings, it can be concluded that the effluent from the wastewater treatment plant is not yet effective in meeting the wastewater quality standards. However, it is worth noting that the pH parameter meets the wastewater quality standards, with an increase of +1.38 compared to the influent pH level. Therefore, in terms of this parameter, the wastewater treatment plant can be considered effective in raising the pH.
References
Rahmawati. P., 2014. “Pengelolaan Metode IPAL ( Instalasi Pengolahan Air Limbah) Dalam Mengatasi Pencemaran Air Tanah Dan Air Sungai”. Universitas Muhammadiyah Surakarta: Surakarta.
Fatkhurrohman. A., 2022. “Perancangan Bangunan Instalasi Pengolahan Air Limbah (IPAL) Tahu (Studi Kasus Industri Tahu di Dusun Janten, Ngestiharjo, Kasihan, Bantul)”. Universitas Sarjanawiyata Tamansiswa: Yogyakarta.
Badan Standarisasi Nasional. SNI 6989.11:2019: Air dan air limbah – Bagian 11: “Cara uji derajat keasaman (pH) dengan menggunakan pH meter”. Jakarta.
Badan Standarisasi Nasional. (2019). SNI 6989.3:2019 Air dan air limbah – Bagian 3: “Cara uji padatan tersuspensi total (Total Suspended Solids, TSS) secara gravimetri”. Jakarta.
Badan Standarisasi Nasional. SNI 6989.73:2019: Air dan air limbah – Bagian 73: “Cara uji kebutuhan oksigen kimiawi (chemical oxygen demand/COD) dengan refluks tertutup secara titrimetri”. Jakarta.
Badan Standarisasi Nasional. SNI 6989.72:2009 “Cara Uji BOD5”. Jakarta.
Badan Standarisasi Nasional, SNSU PK.K-01:2022, “Panduan Pengukuran pH dengan Teknik Kalibrasi Dua Titik”. Jakarta.
Peraturan Daerah Daerah Istimewa Yogyakarta Nomor 7 Tahun 2016, tentang “Baku Mutu Air Limbah”, bagian Baku Mutu Air Limbah Untuk Kegiatan Industri Tahu.
Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia Nomor 5 Tahun 2014, Tentang Baku Mutu Air Limbah. Menteri Lingkungan Hidup Dan Kehutanan Republik Indonesia: Jakarta.
Sasiang. E., Maddusa. S.S., dan Sumampouw. O.J., 2019. “Efektivitas Instalasi Pengolahan Air Limbah Berdasarkan Parameter Biological Oxygen Demand, Chemical Oxygen Demand Dan Derajat Keasaman Di Rumah Sakit Umum GMIM Pancaran Kasih Manado”. Universitas Sam Ratulangi: Manado.
Wijayaningrat. A. T. P., 2018, “Evaluasi Kinerja IPAL Komunal Di Kecamatan Banguntapan Dan Bantul, Kabupaten Bantul, D.I. Yogyakarta Ditinjau Dari Parameter Fisik Kimia”. Universitas Islam Indonesia: Yogyakarta.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Proceedings Series on Physical & Formal Sciences
This work is licensed under a Creative Commons Attribution 4.0 International License.