Radiation Dose Optimization: Range Configuration on Computed Tomography Scans of Non-Contrast Head Scans with Hemiparese Cases

Authors

  • Alya Verina Universitas Muhammadiyah Purwokerto, Indonesia
  • Fannisa Rahma Pradika Universitas Muhammadiyah Purwokerto, Indonesia
  • Arga Pratama Rahardian Universitas Muhammadiyah Purwokerto, Indonesia
  • Farid Setialam Universitas Muhammadiyah Purwokerto, Indonesia

DOI:

https://doi.org/10.30595/pshms.v6i.1415

Keywords:

CT Scan, CT Scan Head Hemiparese, CTDivol, DLP, Hemiparese

Abstract

Approximately 80% of stroke patients experience weakness/hemiparesis on one side of the body due to vascular abnormalities in certain hemispheres. If hemiparese is not treated immediately, it can cause permanent disability. Supporting examination that can be used to diagnose hemiparese is a non-contrast head CT scan. There are several ranges that can be applied to the examination. This affects the dose received by the patient. This study aims to compare the radiation dose (CTDIvol and DLP) in non-contrast head CT scan examination in hemiparese cases between the range from vertex to sinus maxillaris and the range from vertex to basic cranii. The research was conducted at KRT Setjonegoro Wonosobo Hospital in December 2023 using quantitative method. Data were obtained from a non-contrast head CT scan examination with hemiparese cases using the range vertex to sinus maxillary and range vertex to basic crani. Results: In the head CT Scan examination of hemiparese cases, the CTDIvol value for the range Vertex to sinus maxillaris and the range Vertex to basic cranii is 45.5 ± 12.6 mGy and 48.8 ± 14.6 mGy, while for the DLP for the range Vertex to sinus maxillaris is 609.8 ± 47.9 mGy.cm and for the range Vertex to basic cranii is 878.9 ± 42.1 mGy.cm. CTDIvol value is found to have no significant difference, but for the DPL value there is a significant difference in the non-contrast head CT scan examination without contrast with hemiparese cases The 2 CTDIvol and DLP values are still in accordance with the DRL recommendations recommended by Nuclear Energy Regulatory Agency (BAPETEN).

References

J. Julianto, Solikin, and M. Firdaus, “Hubungan Prehospital Delay Dengan Tingkat Keparahan Pada Pasien Stroke Di Rumah Sakit Banjarmasin,” J. Nurs. Invent., vol. 3, no. 2, pp. 108–116, 2023, doi: 10.33859/jni.v3i2.274.

S. Susanti, S. Susanti, and D. N. BIstara, “Pengaruh Range of Motion (ROM) terhadap Kekuatan Otot pada Pasien Stroke,” J. Kesehat. Vokasional, vol. 4, no. 2, p. 112, 2019, doi: 10.22146/jkesvo.44497.

Jahra Alhamid, N. Norma, and O. Lopulalan, “Analisis Faktor Risiko Terhadap Kejadian Stroke,” Nurs. Arts, vol. 12, no. 2, pp. 100–109, 2018, doi: 10.36741/jna.v12i2.82.

Y. A. Virgin, K. Y. Astina, and S. Pratista, “Estimasinilai dosis radiasi pada pemeriksaan CT-Scan Kepala Dewasa Non Kontras berdasarkan nilai CTDI dan DLP di Instalasi Radiologi RS TK II Pelamonia,” Naut. J. Ilm. Multidisiplin, vol. 1, no. 10, pp. 1147–1152, 2023, [Online]. Available: https://jurnal.arkainstitute.co.id/index.php/nautical/article/view/536/458

P. I. Wulandari, N. P. R. Jeniyanthi, I. M. L. Prasetya, I. P. A. Susanta, I. P. E. Juliantara, and A. . A. Diartama, “Evaluasi Dosis Radiasi Pada Pemeriksaan Radiografi Thorax,” Prepotif J. Kesehat. Masy., vol. 7, no. 3, pp. 16325–16330, 2023, doi: 10.31004/prepotif.v7i3.19824.

R. Annisah, “Penentuan Nilai Diagnostic Reference Level CT-Scan di Rumah Sakit Universitas Tanjungpura Pontianak,” Prism. Fis., vol. 10, no. 3, p. 387, 2023, doi: 10.26418/pf.v10i3.59891.

R. M. Khoriyyah, “Estimasi Dosis Radiasi Dan Faktor Risiko Pada Pemeriksaan Computed Tomography Scan Abdomen Di Rumah Sakit Islam (Rsi) Sultan Agung Semarang,” Skripsi, p. 1, 2020.

C. Andre, “Efek Radiasi Sinar-X Pada Pemeriksaan Radiologi Terhadap Janin.” 2020.

BAPETEN, “Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level) Untuk Modalitas Sinar-X Ct Scan Dan Radiografi Umum,” Angew. Chemie Int. Ed. 6(11), 951–952., pp. 2013–2015, 2021.

Mahendra. R. A. 2020. Prosedur Pemeriksaan CT Scan Kepala Pada Kasus Stroke Hemorragic. Poltekes Kemenkes Semarang. http://repository.poltekkes-smg.ac.id//index.php?p=show_detail&id=23010

P. Utami, I. Andriani, and T. Budiwati, “Prosedur Pemeriksaan CT Scan Kepala Pada Kasus Cerebrovascular,” J. Ilmu dan Teknol. Kesehat., vol. 4, no. 2, pp. 16–19, 2018.

Khallouqi, A., Halimi, A., & El Rhazouani, O. 2024. Assesment of CTDI for tube voltage variations in an eoxy and polyster-resin phantom using the platform GEANT4/GATE. Radiation Physisc and Chemistry. 214. https://doi.org/10.1016/j.radphyschem.2023.111285

K. Y. Kristinayanti Ni Kadek Dwik, Iffah Maghfirotul, Jeniyanthi Ni Putu Rita, “Analisis Pengaruh Scan Length Terhadap Nilai Dose Length Product Pada CT Scan Multislice di RSUD Mangusaha Badung.”

Downloads

Published

2025-01-17

How to Cite

Verina, A., Pradika, F. R., Rahardian, A. P., & Setialam, F. (2025). Radiation Dose Optimization: Range Configuration on Computed Tomography Scans of Non-Contrast Head Scans with Hemiparese Cases. Proceedings Series on Health & Medical Sciences, 6, 127–130. https://doi.org/10.30595/pshms.v6i.1415