Evaluasi Sistem Proteksi Penangkap Petir pada Gedung Rektorat dan Gedung KH AR Fachruddin di Lingkungan Universitas Muhammadiyah Purwokerto

Penulis

  • Winarso Winarso Universitas Muhammadiyah Purwokerto
  • Zyon Ridho Universitas Muhammadiyah Purwokerto

DOI:

https://doi.org/10.30595/pspfs.v6i.859

Kata Kunci:

Sistem Penangkap Petir, SNI 03-7015-2004, PUIPP

Abstrak

Universitas Muhammadiyah Purwokerto has numerous buildings, including the rectorate and the 55.27-meter-tall K.H. A.R. Fachruddin building, that could be struck by lightning and as a result, it require an efficient lightning arrester system (SPP). This study aims to evaluate the building's lightning safety level in compliance with SNI 03-7015-2004, the General Regulations for Lightning Protection Installation (PUIPP), and the building's lightning arrester system's state. Direct measurements of building structures, lightning arrester system components, lightning arrester conditions, and soil resistance are employed to collect research data using the observational approach. The study calculates the degree of protection in structures in accordance with the General Regulations for Lightning Protection Installation (PUIPP) standards and determines the value of the protection range using SNI 03-7015-2004. Both the KH AR Fachruddin building and the rectorate building have an R index of 14, which means that they both desperately need an efficient lightning arrester. The Rector building's system is only 75% effective, compared to 91% in the KH AR Fachruddin building.

Referensi

Saragih, B., Siburian, J. M., & Purba, J. L. (2020). Sistem Penangkal Petir Pada Gedung Kemang Gallery Medan. Jurnal Teknologi Energi Uda: Jurnal Teknik Elektro, 9(1), 44-61.

Murdiya, F. (2017). Sistem Proteksi Petir Eksternal Pada Gedung Baru Fakultas Teknik Universitas Riau. Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains, 4(2), 1-12..

Chen, Y. H. A., Lin, K. J., & Li, Y. C. M. (2017). Assessment To Effectiveness Of The New Early Streamer Emission Lightning Protection System. International Journal On Smart Sensing And Intelligent Systems, 10(1), 1-26. [4] S. dan I. K. T. I Wayan and I. K. TA, “Analisis Penggunaan Saklar Arus Bocor ( ELCB ) Sebagai Proteksi Tegangan Sentuh Terhadap Manusia,” Logic, vol. 14, no. 1, pp. 33–39, 2014.

Hosea, E., Iskanto, E., & Luden, H. M. (2004). Penerapan Metode Jala Sudut Proteksi Dan Bola Bergulir Pada Sistem Proteksi Petir Eksternal Yang Diaplikasikan Pada Gedung W Universitas Kristen Petra. Jurnal Teknik Elektro, 4(1). [6] S. Bandri, “Sistem Proteksi Petir Internal Dan Ekternal,” J. Tek. Elektro ITP, vol. 3, no. 1, p. 6, 2014.

Rani, D. (2019). Pemrograman Desain Sistem Penangkal Petir Eksternal Pada Gedung Bertingkat Berbasis Java.

Lubis, Z., Aryza, S., & Annisa, S. (2019). Metode Terbaru Perancangan Proteksi Petir Eksternal Pada Pembangkit Listrik. Jet (Journal Of Electrical Technology), 4(1), 26-34.

Karta, A., Agung, A. I., & Widyartono, M. (2020). Analisis Kebutuhan Sistem Proteksi Sambaran Petir Pada Gedung Bertingkat. Jurnal Teknik Elektro, 9(3), 773-780.

M. Fauzi, M. Raudhi Azmi, T. Multazam, and P. Teknik Elektro, “Ajeetech 23,” vol. 1, pp. 23–28.

Rohani, R. (2017). Evaluasi sistem penangkal petir eksternal di gedung rektorat universitas negeri yogyakarta. Jurnal Edukasi Elektro, 1(2)..

Prasetyo, R. (2017). Penentuan Kebutuhan Proteksi Petir Pada Gedung Bertingkat Kantor Bpjs Ketenagakerjaan Cabang Blitar. Jurnal Qua Teknika, 7(2), 27-42.

Budiman, I. Evaluasi sistem proteksi petir ayani megamal kota pontianak. Jurnal Teknik Elektro Universitas Tanjungpura, 1(1).

Saini, M., Yunus, A. S., & Pangkung, A. (2016). Pengembangan Sistem Penangkal Petir dan Pentanahan Elektroda Rod dan Plat. INTEK: Jurnal Penelitian, 3(2), 66-71..

Lasut, G. F. (2015). Perencanaan Sistem Penangkal Petir Pada Laboratoriumsistem Tenaga Dan Bengkel Jurusan Teknik Elektro Politeknik Negeri Manado (Doctoral Dissertation, Politeknik Negeri Manado).

Diterbitkan

2023-10-13

Cara Mengutip

Winarso, W., & Ridho, Z. (2023). Evaluasi Sistem Proteksi Penangkap Petir pada Gedung Rektorat dan Gedung KH AR Fachruddin di Lingkungan Universitas Muhammadiyah Purwokerto. Proceedings Series on Physical & Formal Sciences, 6, 101–113. https://doi.org/10.30595/pspfs.v6i.859